Every storey needs a smoke alarm, bedrooms or not, and more than one means interconnected.
The rule is one alarm per storey, not one per sleeping area, so the lower floor with no bedrooms still gets one, and once there are two they are interconnected, mains powered where mains power is supplied, and to AS 3786. This is the most common smoke alarm pushback, and the certifier wins it every time.
The answer. The certifier is right. In a Class 1a house every storey needs a smoke alarm, including a storey with no bedrooms, and once there is more than one alarm they must all be interconnected, mains powered where mains power is supplied, and comply with AS 3786.
ABCB Housing Provisions Standard (NCC 2022), Schedule 5 New South Wales, NSW 9.5.1 Smoke and heat alarm requirements, p. 477